Quasi-Fire Resistant Systems |
| Quasi-Fire Resistant Walls with Fire Resistance of up to 45 minutes Accredited by Ministry of Land, Infrastructure and Transport in Japan (The accreditation was obtained by Yoshino Gypsum) |
- The standard quasi-fire resistant walls incorporating the standard plasterboard, Tiger Board and the hard plasterboard, Tiger Super Hard
| Name of Wall | Wall Structure (Horizontal Sectional View) |
| Yoshino Quasi-Fire Resistant Super Wall C | ![]() *Joint treatment is required. |
| Yoshino Quasi-Fire Resistant SF45 | ![]() |
| Yoshino Quasi-Fire Resistant WF45 | ![]() * Conventional Wood Frame Construction |
| Yoshino Quasi-Fire Resistant WP45 | ![]() * Two-by-Four System |
*Loadbearing : Wall systems which bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings
| Quasi-Fire Resistant Walls with Fire Resistance of up to 60 minutes Accredited by Ministry of Land, Infrastructure and Transport in Japan (The accreditation was obtained by Yoshino Gypsum) |
- The quasi-fire resistant walls incorporating the new type of paperless plasterboard Tiger Glass Rock
| Wall Structure (Horizontal Sectional View) |
![]() |
| Quasi-Fire Resistant Walls with Fire Resistance of up to 45 minutes or 60 minutes Accredited by Gypsum Board Industry Association |
| Quasi-Fire Resistance | Wall Structure (Horizontal Sectional View) |
| 45 minutes | ![]() *Joint treatment is required. *Structural steel materials used for bearing vertical loads shall be 2.3 mm thick or more. |
![]() *Joint treatment is required for 9.5 mm water resistant plasterboards. |
|
| 60 minutes | ![]() *Joint treatment is required. *Structural steel materials used for bearing vertical loads shall be 2.3 mm thick or more. |
*Loadbearing : Wall systems which bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings
| Quasi-Fire Resistant Walls which meet the requirements specified by National Land and Transportation Ministry in Japan |
| Quasi-Fire Resistance | Wall Structure (Horizontal Sectional View) |
| 45 minutes | ![]() * Use studs and components made of wood or steel |
![]() * Use studs and components made of wood or steel |
|
![]() * Use studs and components made of wood or steel |
|
![]() * Do not use noncombustible studs or any other noncombustible components (e.g. bonded wood). |
| Quasi-Fire Resistance | Wall Structure (Horizontal Sectional View) |
| 60 minutes | ![]() *Backside of wall shall be batten (only when one layer of board is applied to each side of wall) *Use studs and components made of wood or steel |
![]() *Use studs and components made of wood or steel |
|
![]() *Use studs and components made of wood or steel |
|
![]() *Use studs and components made of wood or steel |
*Loadbearing : Wall systems which bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings
*Non-loadbearing : Wall systems which do not bear loads from buildings